BELT TENSIONERS
John Deere engines use two types of belt tensioners: manual and automatic. Adjust the belt using the manual
tensioner according to the manufacturers specifications. The automatic tensioner cannot be adjusted or repaired
and is designed to maintain proper tension over the belt’s life. Units with the automatic belt tensioner must be inspected
according to the manufacturer’s specifications.
EXHAUST FILTER SERVICE REQUIREMENTS
The exhaust filter system contains a Diesel Particulate Filter (DPF). Over time, the DPF will require professional
servicing to remove ash buildup. The expected service interval will be at least 3,000 or 4,500 hours, based on engine
power and operating conditions. Actual service should take place when the indicator light appears on the Power
Zone™ controller. The DPF should be cleaned or replaced by an authorized service provider only. The removal of
DPF ash must be done by removing the DPF from the unit and placing it into specialized equipment.
CAUTION
Do not remove ash by using water or other chemicals. Removing ash by these methods
may cause equipment damage and create unsafe operating conditions.
CAUTION
Only a qualified service provider should remove, handle and dispose of DPF ash. These
materials may be considered hazardous under federal, state and local regulations, and must
be handled and disposed of properly.
To avoid unnecessary buildup of diesel particulates or soot in the exhaust filter system:
1. Utilize the Automatic Exhaust Filter Cleaning mode.
2. Avoid unnecessary idling.
3. Use proper engine oil. Refer to the engine operator’s manual.
4. Use only ultra low sulfur diesel fuel. Refer to the engine operators manual.
ECU OVERRIDE SWITCH
The ECU override switch is located inside the control box. This toggle switch powers
up the ECU without having to start the engine. Use the ECU override switch to turn
the ECU off. If the unit needs to be shut down immediately, use the emergency stop
switch. Refer to “Emergency Stop Switch” on page 31 for additional information.
DO NOT start the engine with the ECU override switch on.
Doing so will damage the ECU.
CHECKING GENERATOR DRIVE PLATE TORQUE
Follow the procedure below to check the torque of the generator drive plate bolts in accordance with the maintenance
chart. Refer to “Basic Maintenance Schedule - John Deere Engine” on page 41.
1. Disconnect the engine starting battery.
2. Remove the generator fan guard.
3. Torque each of the drive plate bolts to the appropriate specification shown in the table below.
Unit ft-lbs (Nm)
MMG130D 36 (49)
00420