Marathon 1100 SL Instructions d'exploitation Page 16

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 35
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 15
Safety Instructions
Keep children, disabled persons, and animals away from the door.
Keep your hands clear of a door in operation and any moving parts.
Only drive into and out of the garage when the door is fully opened.
There is a risk of persons getting trapped or cutting themselves in/on the
door system’s moving parts or the edges where it closes.
Open and close the door
Command transducers (for example button, manual transmitter, etc.)
Activate 1 x.
Door opens.
- Inside: Button connection 1 (terminals 2 +3) / radio channel 1
- Outside: Button connection 2 (terminals 4 + 5) / radio channel 2
Door closes automatically after expiration of the set time
(warning time, clearance time, and hold open time).
Emergency Release
Risk of damage!
When operating the emergency release, it is possible that the
door may open or close on its own due to the spring breaking or
the weight balance being set incorrectly. Operator can suffer
damage or be destroyed.
The operator can be engaged or disengaged in any door position.
Pull once on the emergency release cord (N): the operator disengages
and the door can be opened manually.
Pull on the emergency release cord (N) once again: The operator
locks into position; door can only be moved with the operator.
If door is fitted with a slip door but no safety mechanism for the slip
door - then install a slip-door safety mechanism (see “Accessories”).
If the door does not have a slip door and if the garage does not have
a second entrance - install a release lock or Bowden cable to provide
outside release access (see “Accessories” instructions).
N
N
Resetting the control unit
Push buttons (1 + 2) until the red signal lights flash.
Red signal lights flash, force settings have been deleted; release
button (1 + 2).
Overload Protection
If the operator is subjected to excessive strain when opening or closing the
door, this is recognised by the control unit which then stops the operator.
After app. 20 seconds or a control unit reset, the control unit deactivates the
overload protection mechanism.
The operator can now recommence normal operation.
Operation following a power failure
The force values remain in memory even during a power failure. The
first travel movement of the operator following a power failure is always
door OPEN.
Adjusting warning time OPEN
Adjustment with TorMinal *
Memory slot (mem) Setting range Factory setting
027 0 - 255 16
(0 ...63.75 seconds) (4 seconds)
Setting the CLOSE warning time
Setting with TorMinal *
Memory slot (mem) Setting range Factory setting
028 0 - 255 20
(0 ...63.75 seconds) (5 seconds)
Setting the clearance time
Setting with TorMinal *
Memory slot (mem) Setting range Factory setting
032 0 - 255 40
(0 ...63.75 seconds) (10 seconds)
Setting the hold open time
Setting with TorMinal *
Memory slot (mem) Setting range Factory setting
031 2 - 255 30
(2 ...255 seconds) (30 seconds)
* TorMinal
L
E
D
1
LED1
L
E
D
2
LED2
L
E
D
3
LED3
L
E
D
4
LED4
T
1
T1
P
2
P2
P
1
P1
T
2
T2
O
N
O
F
F
m
a
x
.
O
p
tio
n
s
S
ta
r
t
C
o
d
e
1
1
2
8
1
1
2
8
S
tar
t
S
a
f
e
ty
W
L
Force
L
E
D
1
LED1 L
E
D
2
LED2 L
E
D
3
LED3 L
E
D
4
LED4
T
1
T1
P
2
P2
P
1
P1
T
2
T2
O
N
O
F
F
m
a
x
.
O
p
tio
n
s
S
ta
r
t
C
o
d
e
1
1
2
8
1
1
2
8
S
tar
t
S
a
f
e
ty
W
L
Force
1
2
ON
OFF
max.
Options Start Code
1
12
81
12
8
S
ta
r
t
S
a
f
e
ty
W
L
Powe
r
Au
to
T
im
e
Fo
rc
e
Start
Code
21
Operation and Handling
15
Vue de la page 15
1 2 ... 11 12 13 14 15 16 17 18 19 20 21 ... 34 35

Commentaires sur ces manuels

Pas de commentaire