Initial Operation
Safety Instructions
Very important to note!
The force setting is relevant to the system's safety and must
therefore be carried out with due care and attention. An
excessively high force setting can injure people and/or animals
and damage property.
Select as low a force setting as possible to ensure that
obstacles are identified in a fast, safe manner.
Keep your hands clear of a door in operation and any moving parts.
Keep children, disabled persons and animals away from the door.
Only drive into and out of the garage when the door is fully opened.
Store the manual remote control such that there is no risk of it being
accidentally operated, by for instance, children or animals.
Setting Correct Length of Travel
The distance over which the drive mechanism moves the door can be
increased/reduced by using the cut-out buffer.
Check that the door opens and closes completely. If it does not, its travel
must be adjusted.
Loosen cut-out buffer (4), move it and tighten it until the door closes.
Check the final travel position by opening and closing the door.
If necessary, repeat this process until the door closes completely.
Loosen cut-out buffer (1), move it and tighten it until the door opens.
Check the final travel position by closing and opening the door.
If necessary, repeat this process until the door opens completely.
Programming Force Values
The control unit has an automatic force setting. When the door opens or
closes, the control unit automatically reads in the required force and
memorises it.
Connect mains plug
When filament lamp (3) is not flashing, delete saved force values:
Press push-buttons (3 + 4) and keep depressed until filament lamp
(3) goes out.
- Release push-buttons (1 + 2)
- Force values deleted.
Carry out procedure 2x:
Close door
Press push-button (1) 1x
Door opens as far as limit switch
Lamp (3) and LED (29.11) start to flash
Press push-button (1) 1x
Door closes as far as limit switch
Filament lamp (3) and LED (29.11) flash
Lamp goes out, force values have been memorised.
Important to note!
An additional force tolerance has to be set if, after the force
values have been set, the drive mechanism does not reach its
final travel positions.
Do not set any additional force tolerance if the drive mechanism
reaches its final travel positions correctly.
33
27
33
27
33
26
25
Checking Force Setting
When the force is correctly set, movement of the door in both directions
can be stopped by exerting slight hand pressure.
For each movement of the door, the control unit checks the force values it
has memorised against those required and automatically adjusts the values
accordingly.
The following measures can be taken if the force values set for opening
and closing the door are too high:
- reduce the force tolerance
- delete the force values by initiating a control reset and set the new
values
- check door
Setting Correct Force Tolerance
Check force adjustment on a regular basis, every year at least, to
ensure correct functioning. See 'Maintenance and Care' section.
If the force is insufficient to allow the full opening or closing of the door, the
tolerance can be increased by turning the adjustment on the potentiometer
in a clockwise direction.
The maximum force value allowed is automatically made up of the force
read in together with an additional force tolerance set via the potentiometer
(29.14). The potentiometer's furthest anticlockwise setting (-) is equivalent
to the least force tolerance, and its furthest clockwise setting the largest for-
ce tolerance. If the setting is adjusted during opening or closing door, the
new setting is read in by the control unit when the door is next re-opened or
closed.
Once the force tolerance has been set, you may have to re-adjust the door
OPEN and CLOSED final travel positions if the required position is not
reached.
Procedure:
Close door.
Engage bogie unit:
pull once on the emergency release wire (N) if bogie unit
disengages.
Remove control unit housing lid (1).
Turn potentiometer adjustment (1) as far anticlockwise as possible
(4).
If filament lamp (3) does not flash - delete set force values:
Press push-buttons (3 + 4) and keep depressed until filament lamp
(3) goes out.
- Release push-buttons (1 + 2).
- Force values deleted.
If filament lamp (3) flashes - read in force values:
Press push-button (1) 1x
Door opens to limit switch without stopping
Press push-button (1) 1x
Door closes to limit switch without stopping
Press push-button (1) 1x
Door opens to limit switch without stopping
Press push-button (1) 1x
Door closes to limit switch without stopping
Force values for opening and closing have thus been taught.
Filament lamp lights up.
Test run:
Press push-button (1) 1x
Door opens to limit switch without stopping
Press push-button (1) 1x
Door closes to limit switch without stopping
The force value has to be increased if the door does not reach its
final travel position providing the travel length has been set correctly.
Turn potentiometer (1) approx. 10 degrees in a clockwise direction (5).